YX-T503 White Anticorrosive Silicone-based Coating


Keywords

Yanxun, silicon material, organic


Classification

600℃ anti-corrosion special silicon-based coating


Product Details


Product Introduction


YX-T503 is a high-temperature, corrosion-resistant thermosetting coating formulated with pigments such as titanium dioxide, boron nitride, and reinforcing silica powder. The coating can withstand temperatures up to 600℃, is dense, waterproof, and resistant to aging. It is suitable for reflective heat insulation and corrosion-resistant topcoats, metallurgical high-temperature components, boilers, high-temperature sensor components, ovens, engine exhaust pipes, and other high-temperature corrosion-resistant applications.

 

Performance Highlights

Testing Items

Performance Indicators

Testing Methods

Coating Composition

Single Component

 

Coating Mixed Color

White

Visual Inspection

Mixed Coating Density (g/mL)

1.45~1.55

GB/T 6750-2007

Mixed Coating Viscosity (涂-4杯)

28~35s

GB/T 1723-1993

Non-Volatile Matter (180±2℃)

70%~75%

GB/T 1725-2007

Hardness (Pencil, 250℃ curing)

≥6H

GB/T 6739-2022

Adhesion (Cross-Cut Test)

Grade 0

GB/T 9286-1998

Neutral Salt Spray Resistance

>1000h

GB/T 10125-2021

Artificial Weathering Resistance

28d No rust, no powdering, no cracking, no discoloration

GB/T 14522-93

Thermal Shock Test (Air Cooling)

600℃/6h No visible cracking, no discoloration

GB/T 30873-2014

Flexibility, Mandrel Diameter (mm)

1

GB/T 1731--1993

Impact Test (㎝)

50

GB/T 1732--1993

Recoatability

Multiple recoats OK

Actual Measurement

Contact Insulation Test (250℃)

AC: >500V;-DC: >4KV

RK2674A External Connection

Contact Insulation Test (600℃)

AC: >200V;-DC: >800V

RK2674A External Connection

 

Construction Guide


Air Spray

Recommended Data

Film Thickness (µm)

20

40

70

Greater than 100

 

Dry Hardness (H)

6

6

6

5

 

Coating Visual Inspection

Easy to Produce Color Difference

Color Saturation

Color Saturation

High Temperature Cracking

 

Surface Dry Time (h)

>5 days Coating is soft (not applicable for room temperature curing)

 

Fast Curing Recommendation

230℃/1h or 250℃/0.5h

Item

Operating Parameters

Item

Parameters

Coating Non-Volatile Matter (%)

>70 (Original Solution Spraying)

Flash Point (℃)

<22 (Solvent Flash Point)

Theoretical Spreading Rate (m 2 /kg)

6~10

Volatility

Solvent Easily Volatile

Pot Life

Exposed to Air, 12 Hours

Instantaneous Maximum Temperature Resistance (℃)

700

Thinner

Silane, Lipids, Alkanes, etc.

Recommended Application Temperature (℃)

-30 to 600

Dilutable Limit

0—20%

Storage (℃)

0-30

Special Note: YX-T503 is a thermosetting product. Products exposed to air should be used within 12 hours. During prolonged construction, cleaning of construction tools should be done to prevent tools from solidifying. It is recommended that one spray or brush coat be completed, and the dry film thickness should not exceed 100μm, otherwise the coating is prone to sagging. High temperature can improve coating hardness and reduce color difference under the same film thickness.

 

Laboratory Construction Methods

Spraying Process

Operating Instructions

Remarks

Surface Roughening

Before coating, the substrate surface should be polished or sandblasted to remove rust, dust, dirt, etc. adhering to the substrate surface. The optimal level is Sa2.5, and the minimum is St3 grade without scale (GB/T 30790.4-2014).

This operation may not be necessary for clean substrates.

Surface Cleaning

Remove residual oil, dust, etc. on the roughened surface with a special cleaning agent or degreaser.

This affects adhesion.

Substrate Drying

Before coating, ensure that the substrate surface is dry and clean.

This affects adhesion.

Coating Preparation

Stir the product for 3-5 minutes, weigh according to construction needs, and filter with 120 to 300 mesh for later use.

 

Coating Application

Laboratory spray coating method: 1.0 caliber spray gun provides better appearance and uniformity. After curing, the coating has a certain hydrophobic and oleophobic property, but it does not affect repeated coating.

Clean the gun with alkanes, lipids, ethers, etc.

Curing

Refer to air spray data. During the curing process, the solvent volatilizes and produces a small amount of ammonia gas. Testing on Q235B plate material shows that curing can be achieved by heat preservation at 230℃ for 1 hour. For complex substrates, the temperature can be increased or the time can be extended.

High-temperature testing should use temperature-resistant substrates.

 

Product Storage


1. Storage must comply with national regulations. The storage environment should be dry, cool, and well-ventilated, away from heat sources and fire sources. The packaging containers must be kept sealed and carefully placed.

2. This product contains physically adsorbed or chemically bonded ammonia; therefore, sufficient preventive measures should be taken during handling and material processing. This product is water-sensitive and can react with oxidants, alcohols, acids, and alkalis. Maintain appropriate spacing during storage.

3. The storage temperature should be between 5℃ and 30℃, and the shelf life is 12 months.

4. Unopened and unused coatings must be sealed with the lid. If necessary, purge with nitrogen before sealing.

5. Unused mixed coatings cannot be recycled and should be disposed of according to local regulations.

6. Products that have exceeded the shelf life can be used only after passing the inspection.

—☆☆☆☆☆—

 

Jiangxi Yanshun Silicon Materials Co., Ltd.

Address: Xinghuo, Yongxiu County, Jiujiang City, Jiangxi Province

West side of Xingyun Avenue, Industrial Park

Tel: Mr. Jiang 133 8103 8358 191 6503 7579

 

Special Statement: The information provided above is entirely based on the knowledge we have gained in the laboratory and practice. The use of the product is usually beyond our control, so we only guarantee the quality of the product itself. The product may be adjusted appropriately to meet local regulations. We reserve the right to modify the instructions without further notice. Users should consult our company for specific guidance on the applicable performance of the product based on their own needs and specific applications.

Message consultation


Submit immediately