Product Details


Product Introduction


YX-T501 is a high-temperature, corrosion-resistant thermosetting coating formulated with pigments such as copper chromium black, boron nitride, and reinforcing silica powder. The coating can withstand temperatures up to 600℃, and is dense, waterproof, and resistant to aging. It is suitable for high-temperature corrosion prevention in applications such as cookware (lids, rice cookers), metallurgical high-temperature components, boilers, high-temperature sensor components, ovens, and engine exhaust pipes.

 

Performance Highlights

Test Items

Performance Indicators

Testing Methods

Coating Composition, Color

Single-component, Black

Visual Inspection

Coating Mixed Density (g/mL)

1.45~1.55

GB/T 6750-2007

Coating Mixed Viscosity (涂-4杯)

25~35s

GB/T 1723-1993

Non-volatile Matter (180±2℃)

70%~75%

GB/T 1725-2007

Hardness (Pencil, 250℃ curing)

≥6H

GB/T 6739-2022

Cross-hatch Adhesion

Grade 0

GB/T 9286-1998

Pull-off Adhesion

6MPa (3.9MPa-6.8MPa), 100%B

GB/T 5210-2006

Water Resistance (Distilled water 23℃, immersion 24h)

No loss of gloss, discoloration, bubbling,

wrinkling, peeling, or rusting.

GB/T 1733-1993

Neutral Salt Spray Resistance

>1000h

GB/T 10125-2021

Artificial Weathering Resistance

28d No rust, no powdering, no cracking, no discoloration

GB/T 14522-1993

Heat Resistance (500℃, 3h, impact resistance test)

No delamination, wrinkling, blistering, cracking,

or discoloration; impact resistance 20cm

GB/T 1735-2009

Thermal Shock Test (Water Quenching Method)

600℃/6h-Five times or more, no visible cracks, no discoloration

GB/T 30873-2014

Flexibility, mandrel diameter (mm)

1

GB/T 1731-2020

Impact Test (cm)

50

GB/T 1732-2020

 

Construction Guide


Air Spray

Recommended Data

Film Thickness (µm)

20

40

60

Greater than 100

 

Dry Hardness (H)

6

6

6

5

 

Visual Inspection of Coating

Easy to produce color difference

Color is full

Color is full

High temperature cracking

 

Surface Dry Time (h)

>5 days coating soft (not suitable for room temperature curing)

 

Recommended Fast Curing

230℃/1h or 250℃/0.5h

Item

Operating Parameters

Item

Parameters

Coating Non-Volatile Matter (%)

>70 (Undiluted spray application)

Flash Point (℃)

<22 (Solvent flash point)

Theoretical Spreading Rate (m 2 /kg)

8~10

Volatility

Solvent easily volatile

Workability Time

Exposed to air, 12 hours

Instantaneous Maximum Temperature Resistance (℃)

700

Thinner

Silane, lipids, alkanes, etc.

Recommended Application Temperature (℃)

-30 to 600

Dilution Limit

0-20%

Storage (℃)

0-30

Special Note: YX-T501 is a single-component thermosetting product. Products exposed to air should be used within 12 hours. During longer construction periods, cleaning of tools should be done to prevent hardening. It is recommended to complete the application in one coat, with a dry film thickness not exceeding 100 microns; otherwise, the coating performance will decrease. High temperature can increase the hardness of the coating at the same film thickness with less color difference.

 

Laboratory Application Method

 

Spray Coating Process

Operating Instructions

Remarks

Surface Roughening

Before coating, grind or sandblast the substrate surface to remove rust, dust, dirt, etc. adhering to the substrate surface. Optimal Sa2.5, minimum St3 grade without scale (GB/T 30790.4-2014).

This operation may not be necessary for clean substrates.

Surface Cleaning

Remove residual oil, dust, etc. from the roughened surface using a special cleaning agent or degreaser.

This affects adhesion, etc.

Substrate Drying

Before coating, ensure that the substrate surface is dry and clean.

This affects adhesion, etc.

Coating Preparation

Stir the product for 3-5 minutes, weigh as needed, and filter through a 120 to 300 mesh sieve for use.

 

Coating Application

For laboratory spraying, a 1.0 nozzle spray gun is used for better appearance and uniformity. After curing, the coating has a certain water and oil repellency, but this does not affect repeated coating. The total film thickness should be less than 100 microns.

Clean the gun with alkanes, lipids, ethers, etc.

Curing

Refer to air spray data. The curing process is accompanied by solvent evaporation and the generation of a small amount of ammonia gas. Testing on Q235B plate material shows that curing can be achieved at 230℃ for 1 hour. For complex substrates, the temperature can be increased or the time extended.

High-temperature testing should use temperature-resistant substrates.

 

Product Storage


1. Storage must comply with national regulations. The storage environment should be dry, cool, and well-ventilated, away from heat sources and fire sources. The packaging container must remain sealed and carefully placed.

2. This product contains physically adsorbed or chemically bonded ammonia; therefore, sufficient precautions should be taken during handling and material processing. This product is water-sensitive and can react with oxidants, alcohols, acids, and alkalis. Maintain appropriate spacing during storage.

3. The storage temperature should be between 5℃ and 30℃, and the shelf life is 12 months.

4. Unopened and unused coating must be sealed with the lid closed. If necessary, purge with nitrogen before sealing.

5. Unused, prepared coating cannot be recycled and should be disposed of according to local regulations.

6. Products that have exceeded the shelf life can only be used after passing inspection.

—☆☆☆☆☆—

 

Jiangxi Yanshun Silicon Materials Co., Ltd.

Address: Xinghuo, Yongxiu County, Jiujiang City, Jiangxi Province

West side of Xingyun Avenue, Industrial Park

Tel: Mr. Jiang 133 8103 8358 191 6503 7579

 

Special Statement: The information provided above is entirely based on the knowledge we have gained in the laboratory and practice. The use of the product is usually beyond our control, so we only guarantee the quality of the product itself. The product may be adjusted appropriately to suit local regulations, and we reserve the right to modify the instructions without further notice. Users should consult our company to obtain specific guidance on the applicable performance of the product for their own needs and specific applications.

Message consultation


Submit immediately