Product Details
Product Details
Product Introduction
YX-T702 is a flexible, anticorrosive silicone-based coating formulated with aluminum silver paste, silicone-based materials, and reinforcing silicon powder. The coating is touch dry in 4 hours at room temperature, heat-resistant to above 400℃, does not discolor at high temperatures, is fire-resistant, and is dense, waterproof, and aging-resistant. It is suitable for the corrosion prevention and repair of pipe outer walls, chemical facilities, and coastal facilities.
Performance Highlights
| Testing Items |
Performance Indicators |
Testing Methods |
| Coating Composition |
Single Component |
|
| Coating Mixed Color |
Silver White |
Visual Inspection |
| Coating Mixed Density (g/mL) |
1.45~1.55 |
GB/T 6750-2007 |
| Coating Mixed Viscosity (涂-4 cup) |
45~60s |
GB/T 1723-1993 |
| Non-volatile Matter (180±2℃) |
70%~75% |
GB/T 1725-2007 |
| Hardness (Pencil, Room Temperature 48h) |
≥6B |
GB/T 6739-2006 |
| Adhesion by Cross-Cut Test (150μm) |
Grade 0 |
GB/T 9286-1998 |
| Neutral Salt Spray Resistance (150μm) |
>2000h |
GB/T 10125-2021 |
| Artificial Weathering Resistance |
28d No rust, no powdering, no cracking, no discoloration |
GB/T 14522-93 |
| Thermal Shock Test (Air Cooling) |
400℃/6h No visible cracks, no discoloration |
GB/T 30873-2014 |
| Flexibility, Mandrel Diameter (mm) |
0.5 |
GB/T 1731--1993 |
| Impact Test (㎝) |
50 |
GB/T 1732--1993 |
Construction Guide
| Air Spray Recommended Data |
Film Thickness (micrometers) |
60 |
85 |
120 |
Greater than 200 |
||
|
|
Dry Hardness |
5B |
6B |
6B |
6B |
||
|
|
Coating Visual Inspection |
Easy to produce color difference |
Color saturation |
Color saturation |
Easy to sag |
||
|
|
Room Temperature Drying Time (h) |
4h touch dry, 24h surface dry, remains flexible at room temperature for 21 days. |
|||||
|
|
Recommended Fast Curing |
150~180℃ insulation for 30 minutes |
|||||
| Item |
Operating Parameters |
Item |
Parameters |
||||
| Coating Non-volatile Matter (%) |
>70 (undiluted spray application) |
Flash Point (℃) |
<22 (solvent flash point) |
||||
| Theoretical Coating (m 2 /kg) |
3~6 |
Volatility |
Solvent easily volatile |
||||
| Workability Time Limit |
Exposed to air, 12 hours |
Instantaneous Maximum Heat Resistance (℃) |
400 |
||||
| Thinner |
Silane, lipids, alkanes, etc. |
Recommended Application Temperature (℃) |
-30 to 300 |
||||
| Dilutable Limit |
0—20% |
Storage (℃) |
0-30 |
||||
YX-T702 is a single-component, room-temperature curing product. Products exposed to air should be used within 12 hours. During prolonged construction periods, cleaning of tools should be carried out to prevent tools from setting. It is recommended that one spray or brush coat be applied, and the dry film thickness should not exceed 120 micrometers, otherwise the coating may sag. High temperature can increase the hardness of the coating at the same film thickness, and reduce color difference.
Laboratory Construction Methods
| Spray Coating Process |
Operating Instructions |
Remarks |
| Surface Roughening |
Before coating, grind or sandblast the substrate surface to remove rust, dust, dirt, etc. attached to the substrate surface. Optimal Sa2.5, minimum St3 grade without scale (GB/T 30790.4-2014). |
This operation can be omitted for clean substrates. |
| Surface Cleaning |
Remove oil, dust, etc., remaining on the napped surface using a special cleaning agent or degreaser. |
Affects adhesion, etc. |
| Substrate Drying |
Before coating, ensure that the substrate surface is dry and clean. |
Affects adhesion, etc. |
| Coating Preparation |
Stir the product for 3-5 minutes, weigh according to construction needs, and filter with 120 to 300 mesh for later use. |
|
| Coating Application |
Laboratory spray coating method: 1.0 caliber spray gun, better appearance and uniformity. After curing, the coating has a certain water and oil repellency, but it does not affect repeated coating. |
Clean the gun with alkanes, lipids, ethers, etc. |
| Curing |
Refer to the air spray coating data. During the curing process, the solvent volatilizes and produces a small amount of ammonia gas. Testing shows that Q235B plate material can be cured at 230℃ for 1 hour. For complex substrates, the temperature can be increased or the time can be extended. |
High-temperature testing should use temperature-resistant substrates. |
Product Storage
1. Must be stored in accordance with national regulations. The storage environment should be dry, cool, and well-ventilated, away from heat sources and fire sources. The packaging container must be kept sealed and placed carefully.
2. This product contains physically adsorbed or chemically bonded ammonia; therefore, sufficient preventive measures should be taken when using and handling related materials. This product is water-sensitive and can react with oxidants, alcohols, acids, and alkalis. Maintain an appropriate distance during storage.
3. The storage temperature should be between 5℃ and 30℃, and the shelf life is 12 months.
4. Unopened and unused coating must be sealed with the lid closed. If necessary, purge with nitrogen before sealing.
5. Unused mixed coating cannot be recycled and should be disposed of according to local regulations.
6. Products that have exceeded the shelf life can be used only after passing the inspection.
—☆☆☆☆☆—

Jiangxi Yanshun Silicon Materials Co., Ltd.
Address: Xinghuo, Yongxiu County, Jiujiang City, Jiangxi Province
West side of Xingyun Avenue, Industrial Park
Tel: Mr. Jiang 133 8103 8358 191 6503 7579
Special Statement: The information provided above is entirely based on the knowledge we have gained in the laboratory and practice. The use of the product is usually beyond our control, so we only guarantee the quality of the product itself. The product may be adjusted appropriately to suit local regulations, and we reserve the right to modify the instructions without further notice. Users should consult our company to obtain specific guidance on the applicable performance of the product for their own needs and specific applications.
Previous article
Next article
Previous article
Next article
recommend products