Product Details
Product Details
Product Introduction
YX-T703 is a room-temperature curing flexible anticorrosion silicone-based coating, compounded with titanium dioxide, boron nitride, reinforcing silica powder, etc. The coating is touch dry in 4 hours at room temperature, can withstand temperatures above 400℃, does not change color at high temperatures, is flame-resistant, dense, waterproof, and aging-resistant. It is suitable for the anticorrosion and repair of pipeline outer walls, chemical facilities, and coastal facilities.
Performance Highlights
| Test Items |
Performance Indicators |
Test Methods |
| Coating Composition |
Single Component |
|
| Coating Mixed Color |
White |
Visual Inspection |
| Coating Mixed Density (g/mL) |
1.45~1.55 |
GB/T 6750-2007 |
| Coating Mixed Viscosity (涂-4 cup) |
28~35s |
GB/T 1723-1993 |
| Non-volatile Matter (180±2℃) |
70%~75% |
GB/T 1725-2007 |
| Hardness (Pencil, Room Temperature 48h) |
≥6B |
GB/T 6739-2006 |
| Adhesion by Cross-Cut Test (150μm) |
Grade 0 |
GB/T 9286-1998 |
| Neutral Salt Spray Resistance (150μm) |
>2000h |
GB/T 10125-2021 |
| Artificial Weathering Resistance |
28d No rust, no powdering, no cracking, no discoloration |
GB/T 14522-93 |
| Thermal Shock Test (Air Cooling) |
400℃/6h No visible cracking, no discoloration |
GB/T 30873-2014 |
| Flexibility, Mandrel Diameter (mm) |
0.5 |
GB/T 1731--1993 |
| Impact Test (㎝) |
50 |
GB/T 1732--1993 |
| Recoatability |
Multiple recoats OK |
Actual Measurement |
Construction Guide
| Air Spray Recommended Data |
Film Thickness (Microns) |
60 |
85 |
120 |
Greater than 200 |
||
|
|
Actual Dry Hardness |
5B |
6B |
6B |
6B |
||
|
|
Coating Visual Inspection |
Easy to produce color difference |
Color is full |
Color is full |
Easy to sag |
||
|
|
Room Temperature Dry Time (h) |
4h touch dry, 24h surface dry, remains flexible at room temperature for 21 days. |
|||||
|
|
Fast Curing Recommendation |
150~180℃ insulation for 30 minutes |
|||||
| Item |
Operating Parameters |
Item |
Parameters |
||||
| Coating Non-volatile Matter (%) |
>70 (Original solution spraying) |
Flash Point (℃) |
<22 (Solvent flash point) |
||||
| Theoretical Coating (m 2 /kg) |
3~6 |
Volatility |
Solvent is easily volatile |
||||
| Workable Time |
Exposed to air, 12 hours |
Instantaneous Maximum Temperature Resistance (℃) |
400 |
||||
| Thinner |
Silane, lipids, alkanes, etc. |
Recommended Application Temperature (℃) |
-30 to 300 |
||||
| Dilutable Limit |
0—20% |
Storage (℃) |
0-30 |
||||
YX-T703 is a single-component room-temperature curing product. Products exposed to air should be used up within 12 hours. During prolonged construction, the construction tools should be cleaned to prevent solidification. It is recommended to complete the spraying or brushing in one coat, and the dry film thickness should not exceed 120 microns, otherwise the coating is prone to sagging. High temperature can improve the hardness of the coating under the same film thickness and reduce color difference.
Laboratory Construction Method
| Spraying Process |
Operating Instructions |
Remarks |
| Surface roughening |
Before coating, sandblast or grind the substrate surface to remove rust, dust, dirt, etc. adhering to the substrate surface. The best is Sa2.5, and the minimum is St3 grade without scale (GB/T 30790.4-2014). |
Clean substrates may not require this step. |
| Surface Cleaning |
Remove residual oil, dust, etc. on the surface with a special cleaning agent or degreaser. |
Affecting adhesion, etc. |
| Substrate Drying |
Before coating, ensure the substrate surface is dry and clean. |
Affecting adhesion, etc. |
| Coating Preparation |
Stir the product for 3-5 minutes, weigh according to construction needs, filter to 120-300 mesh for later use. |
|
| Coating Application |
Laboratory spray coating method: 1.0 caliber spray gun, better appearance and uniformity. After curing, the coating has certain hydrophobicity and oil repellency, but it does not affect repeated coating. |
Clean the gun with alkanes, lipids, ethers, etc. |
| Curing |
Refer to the air spray data. During the curing process, the solvent volatilizes and produces a small amount of ammonia gas. Testing on Q235B plate material shows that curing can be achieved by heat preservation at 230℃ for 1h. For complex substrates, the temperature can be increased or the time can be extended. |
High-temperature testing should use temperature-resistant substrates. |
Product Storage
1. Must be stored in accordance with national regulations. The storage environment should be dry, cool, and well-ventilated, away from heat sources and fire sources. The packaging container must be kept sealed and placed carefully.
2. This product contains ammonia that is physically adsorbed or chemically bonded. Therefore, sufficient preventive measures should be taken when using and handling materials. This product is water-sensitive and may react with oxidants, alcohols, acids, and alkalis. Maintain appropriate spacing during storage.
3. The storage temperature should be maintained between 5℃ and 30℃, and the shelf life is 12 months.
4. Unopened and unused coatings must be sealed with the lid closed, and purged with nitrogen if necessary, before sealing.
5. Unused mixed coatings cannot be recycled and should be disposed of according to local regulations.
6. Products that have exceeded the shelf life can only be used after passing the inspection.
—☆☆☆☆☆—

Jiangxi Yanshun Silicon Materials Co., Ltd.
Address: Xinghuo, Yongxiu County, Jiujiang City, Jiangxi Province
West side of Xingyun Avenue, Industrial Park
Tel: Mr. Jiang 133 8103 8358 191 6503 7579
Special Statement: The information provided above is entirely based on the knowledge we have gained in the laboratory and practice. The use of the product is usually outside our control, so we only guarantee the quality of the product itself. The product may be adjusted appropriately to meet local regulations. We reserve the right to modify the instructions without further notice. Users should consult our company to obtain specific guidance on the applicable performance of relevant products based on their own needs and specific applications.
Previous article
Previous article
recommend products